Welcome to Dongguan Carno Machinery Co., Ltd. official website!

Heating power type selection calculation method of mold temperature machine


Heating power selection calculation method
Calculation Method of Mold Temperature Controller
1. Special circumstances need to be calculated:
A, seek heater power or refrigeration power KW = W × △ t × C × S / 860 × T
W = mold weight or cooling water KG
Δt = temperature difference between the desired temperature and the starting temperature.
C=specific heat oil (0.5), steel (0.11), water (1), plastic (0.45~0.55)
T=Time to warm up to required temperature (hours)
B. Find the size of the pump
Need to understand the customer's required pump flow and pressure (head)
P (pressure Kg/cm2) = 0.1 x H (head M) x α (specific gravity of heat transfer medium, water = 1, oil = 0.7-0.9)
L (media required flow L/min) = Q (heat required for mold Kcal / H) / C (media than hot water = 1 = 0.45 oil) × △ t (the temperature difference between circulating media into and out of the mold) × α × 60 < Br /> 2. Freezer capacity selection
A, Q (refrigeration amount Kcal/H)=Q1+Q2
Q1 (Kcal/H of heat introduced into the mold) = W (weight of raw material injected into the mold per hour KG) × C × (T1-T2) × S (safety factor 1.5 ~ 2) T1 raw material in the material pipe Temperature; temperature at which T2 finished product is taken out of the mold; heat generated by Q2 hot runner Kcal/H
B, fast algorithm (with hot runner not applicable)
1RT=7~8OZ1OZ=28.3g (including safety factor)
1RT=3024Kcal/H=12000BTU/H=3.751KW
1KW=860Kcal/H1Kcal=3.97BTU
3, cooling tower selection = A + B
A. Injection molding machine
Cooling tower RT = injection engine horsepower (HP) × 0.75 KW × 860 Kcal × 0.4 ÷ 3024
B、Freezer
Cooling tower RT = freezer cold ton (HP) x 1.25
Home - About - Product - Strength - Case - Certificate - News - Feedback - Contact