A Brief Introduction to the Solution to the Faults of Four Major Systems of Industrial Chillers


Industrial Chillers There are four major systems: refrigeration system, electrical system, ventilation system, water system, today Industrial chiller manufacturers for everyone to talk about the four major system failure solution!
First Point: Failure of Refrigeration System in Industrial Chillers
Solution: Check whether the pipelines in the refrigeration system are cracked, damaged, frosted or dew condensation; if there are any air-cooled chiller cooling lines, pipelines and shells, etc. Collision friction, especially in the refrigerant pipeline welding, whether there is leakage in the joint of the air-cooled chiller joint, but where there is leakage, there will be oil (a certain amount of refrigeration oil in the refrigeration system), and a clean soft cloth, The soft paper scrubs the welds at the welds of the pipelines and the joints, and investigates whether there is oil stains or not to detect leakage.
Second point: The ventilation system of the industrial chiller has malfunctioned< Br /> Solution: Check if the air filter, heat exchanger coils and fins are too much dust; the air inlet and outlet are not clear; the fan and fan work is not normal; The size is not normal, the water system is not normal and so on.
The third point: The failure of the air system of the air-cooled chiller

Solutions: Check if the water system is leaking; if the water inlet and outlet are not clear; the pump work is not normal. Listening to the power on and listening to the sound of the compressor of the air-cooled chiller is not normal, whether there is abnormal sound, whether the fan, the pump work noise, noise is not too large and so on. In the air-cooled chiller, the oscillation is fine and the noise is small under normal conditions.

The fourth point:IndustryThe chiller's electrical system has failed
Solution: Check whether the fuses in the electrical system are blown, whether the insulation of the electrical conductors is intact or not, whether the circuit board is cracked, and where the connections are. There is no loose and so on. In particular, whether the electrical connection is a good touch or not, the connection screws and the connector are easily released to form a poor touch.

This article comes from industrial chiller manufacturers www.dgcarno.com.cn